1Gauge (relative) pressure

What a normal pressure gauge shows: the pressure above the air around us.

2Easy definition, and a picture to remember

In one line

Gauge pressure is measured relative to the atmosphere. A gauge open to the air reads zero, even though the real pressure is about 1 bar absolute.

Imagine it

Think of floor numbers in a building. The ground floor is 0, the first floor is +1 and the basement is −1. Gauge pressure uses the surrounding air as its ground floor: above it is positive, below it (a vacuum) is negative.

Memory hook

Gauge = absolute − atmosphere. Open to air reads 0. Below zero means vacuum.

3What changes it, and how

Your gauge reading depends on three things.

1

The real pressure inside

The gauge compares the inside pressure with the outside air.

More absolute pressure inside means a higher reading, one for one.

P_gauge = P_abs − P_atm

2

The atmosphere outside

The gauge's zero is whatever the air pressure is at that moment and place.

The same absolute pressure reads a little higher on a mountain, where the air pushes less.

P_atm falls ≈ 0.11 bar / 1000 m

3

Where it is measured

In a liquid, deeper points are at higher pressure.

A gauge placed lower on a tank reads higher than one placed near the top.

ΔP = ρ · g · Δh

Try it: a gauge subtracts the atmosphere

A gauge reads −0.5 bar. What does that mean?

-10123456+1.99bar gaugeVacuum

The needle shows how far the pressure is above the air outside.

5Units and formulas

Write bar(g), barg, kPa(g) or psig. Pipe and pump datasheets usually mean gauge unless they say abs.

Formulas

  • P_gauge = P_abs − P_atm
  • P_gauge = −1.013 bar is a perfect vacuum (at sea level)

Convert a pressure

bar
1
kPa
100
MPa
0.1
psi
14.504
atm
0.9869
kgf/cm²
1.02
mWC
10.197

Write bar(g) for gauge and bar(a) for absolute so nobody has to guess which one you mean.

6Why it matters, and common mistakes

Why it matters

  • ✓Most gauges, transmitters and datasheet pressures are gauge pressures.
  • ✓Pressure ratings such as PN16 are gauge pressures.
  • ✓Operating limits and alarm settings are almost always written in gauge.

Common mistakes

  • !Using a gauge reading in a formula that needs absolute pressure.
  • !Reading a negative number as a fault. It simply means a vacuum.
  • !Comparing readings from different altitudes without thinking about the zero.

Keep going: more pressure lessons