1Minor losses (K factor)

What valves, bends and reducers cost in pressure.

2Easy definition, and a picture to remember

In plain words

Every valve, elbow, tee and reducer in a line takes some pressure on top of the friction of the straight pipe. Each is given a resistance coefficient K, and its loss is ΔP = K · ρv²/2. They are called minor losses, but in a short line with many fittings they can be the biggest part of the loss.

Imagine it

Drive through a town with a long, straight road and one with many roundabouts and traffic lights. The straight road costs you fuel slowly, metre by metre. Each roundabout costs a chunk at once. The K factor is the price of one roundabout, measured in the same units as the speed of the traffic.

Memory hook

Add up all the K values, multiply by ρv²/2, and you have the loss of the fittings. One globe valve is worth about twenty-three long-radius elbows.

3What decides it, and how

Three things set what a fitting costs.

1

The fitting

Each design disturbs the flow differently. A full-bore ball valve barely does; a globe valve forces a double turn.

K is about 0.05 for a ball valve, 0.3 for a long-radius elbow, 7 for a globe valve.

ΔP = K · ρ · v² / 2

2

Speed

The loss follows the speed squared, like all losses from turbulence.

Double the flow and every fitting costs four times as much.

ΔP ∝ v²

3

How many

Losses add up. Ten elbows cost ten times one.

Adding all K values first gives the total fittings loss in one step.

ΣK = K₁ + K₂ + …

Try it: add fittings to a line and see what each one costs

Which costs more pressure in a line: ten long-radius elbows, or one fully open globe valve?

EEEEGC50 m of straight pipe, 6 fittings
Pipe entrance K 0.50
90° elbow K 0.34
Tee (branch) K 10
Gate valve K 0.151
Ball valve K 0.050
Butterfly valve K 0.40
Globe valve K 70
Check valve K 21
Pipe exit K 10

The fittings cost 0.28 times the friction of the straight pipe

  • 50 m of straight pipe (friction)0.646 bar
  • 4 × 90° elbow (K 1.20) · equal to 5.1 m0.066 bar
  • 1 × Gate valve (K 0.15) · equal to 0.6 m0.008 bar
  • 1 × Check valve (K 2.00) · equal to 8.5 m0.110 bar
Total K of the fittings
3.35
Speed
3.32 m/s
Loss in the fittings
0.184 bar
Total loss of the line
0.830 bar

The straight pipe dominates. The fittings matter less here, but they still add up.

5Units and formulas

K has no unit. Speed in m/s, density in kg/m³: ΔP comes out in Pa (divide by 10⁵ for bar). Equivalent length Le is the length of straight pipe with the same loss: Le = K · D / f.

Formulas

  • ΔP = K · ρ · v² / 2
  • ΣK = K₁ + K₂ + …
  • L_eq = K · D / f
  • Kv = 0.04 · DN² / √ζ

6Why it matters, and common mistakes

Why it matters

  • ✓In short lines the fittings and valves are most of the loss.
  • ✓They are part of the system resistance that decides valve authority and pump head.
  • ✓Choosing a low-K valve (full-bore ball or gate) can save real pumping energy.

Common mistakes

  • !Counting only the straight pipe.
  • !Using a K value for a half-open valve or the wrong size.
  • !Forgetting the entrance and exit of the line.

Keep going: more on valves and systems