Ball valves
A ball with a hole through it: a quarter turn gives fast, tight shut-off.
Step 5 of 6
5Calculations
Three checks make the selection safe: the pressure drop and flow, the torque that sets the operator, and the closing time that protects the pipe from water hammer.
1. Flow and pressure drop
Kv = 0.04·DN² / √ζ · Cv = 1.156·Kv · ΔP = ζ·ρ·v² / 2
- Density
- 1,000 kg/m³
- Velocity
- 1.77 m/s
- ζ
- 0.06
- Kv / Cv
- 1,633 / 1,888
- ΔP
- 0.001 bar
- Drop fully open
- 0.001 bar
The loss coefficient ζ is typical for the port: about 0.06 for a full bore, higher for a reduced bore or a V-port, and it rises steeply as the ball closes. The maker's Cv curve decides the final size.
2. Torque and operator
Tseat = μ·ΔP·A·r · Tdesign = 1.25·max(Tbreak, Trun)
- Seat friction
- 76 N·m
- Seat preload
- 12 N·m
- Stem packing friction
- 2 N·m
- Flow (dynamic) torque
- 0 N·m
- Break-away torque
- 90 N·m
- Running torque
- 55 N·m
- Design torque (with 25 % margin)
- 113 N·m
Operator
The torque is small enough for a lever: a pull of about 188 N on a 0.6 m handle.
3. Closing time and water hammer
tcrit = 2L / a · ΔP ≈ 2·ρ·L·Δv / t (Michaud) · teff = 0.3 · tstroke
- Wave speed
- 1000 m/s
- Stroke time
- 2 s
- Effective closing time (30 % of the stroke)
- 0.6 s
- Critical time 2L / a
- 0.0 s
- Pressure surge
- 0.6 bar
- Allowed surge
- 1.6 bar
- Minimum safe stroke time
- 1 s
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.