← Isolation valves

Ball valves

A ball with a hole through it: a quarter turn gives fast, tight shut-off.

Your dutyClean waterDN 10016 bar20 °C50 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the pressure drop and flow, the torque that sets the operator, and the closing time that protects the pipe from water hammer.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
1.77 m/s
ζ
0.06
Kv / Cv
1,633 / 1,888
ΔP
0.001 bar
Drop fully open
0.001 bar
OKVelocity at most 3 m/s

The loss coefficient ζ is typical for the port: about 0.06 for a full bore, higher for a reduced bore or a V-port, and it rises steeply as the ball closes. The maker's Cv curve decides the final size.

2. Torque and operator

Tseat = μ·ΔP·A·r   ·   Tdesign = 1.25·max(Tbreak, Trun)

Seat friction
76 N·m
Seat preload
12 N·m
Stem packing friction
2 N·m
Flow (dynamic) torque
0 N·m
Break-away torque
90 N·m
Running torque
55 N·m
Design torque (with 25 % margin)
113 N·m

Operator

The torque is small enough for a lever: a pull of about 188 N on a 0.6 m handle.

3. Closing time and water hammer

tcrit = 2L / a   ·   ΔP ≈ 2·ρ·L·Δv / t (Michaud)   ·   teff = 0.3 · tstroke

Wave speed
1000 m/s
Stroke time
2 s
Effective closing time (30 % of the stroke)
0.6 s
Critical time 2L / a
0.0 s
Pressure surge
0.6 bar
Allowed surge
1.6 bar
Minimum safe stroke time
1 s
OKThe closing time is slow enough.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.