← Isolation valves

Butterfly valves

A disc on a shaft that turns a quarter turn: the compact, light valve for large pipes.

Your dutyClean waterDN 20010 bar20 °C300 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the pressure drop at the working opening, the torque that sets the operator, and the closing time that protects the pipe from water hammer.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   ΔP = ζ·ρ·v² / 2   ·   v = Q / A

Density
1,000 kg/m³
Velocity
2.65 m/s
ζ
0.50
Kv
2,263 m³/h
ΔP
0.018 bar
Drop fully open
0.018 bar
OKVelocity at most 3 m/s

The loss coefficient ζ is typical for the size and design, and rises steeply as the valve closes. The maker's flow curve decides the final size.

2. Torque and operator

Tseat = k·D²·(0.6 + 0.4·ΔP/16)   ·   Tbearing = μ·ΔP·π/4·D²·r   ·   Tdyn = Ct·D³·ΔP

Seat friction
61 N·m
Bearing friction
66 N·m
Flow (dynamic) torque
0 N·m
Shut-off torque
127 N·m
Running torque
12 N·m
Design torque (with 25 % margin)
159 N·m

Operator

Gearbox with handwheel

A worm gear with a ratio of about 7 : 1 lets one person turn the valve with about 2 handwheel turns.

3. Closing time and water hammer

tcrit = 2L / a   ·   ΔP = ρ·a·Δv (t ≤ tcrit)   ·   ΔP ≈ 2·ρ·L·Δv / t (Michaud)

Wave speed
1000 m/s
Closing time
3 s
Critical time 2L / a
1.0 s
Pressure surge
8.8 bar
Allowed surge
1.0 bar
Minimum safe closing time
27 s
CHECKToo fast. Close in at least 27 s, or add a surge damper.
  • !The valve closes faster than the safe closing time. A large pressure surge (water hammer) can burst the pipe: close more slowly or add surge protection.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.