← Isolation valves

Knife gate valves

A flat blade that slices through thick, dirty flow: the valve for slurry, sewage, pulp and powders.

Your dutySlurry or solidsDN 2004 bar20 °C180 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the pressure drop with the blade at its working height, the thrust and the operator it needs, and the closing time that protects the pipe from water hammer.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   ΔP = ζ·ρ·v² / 2   ·   ζ = 0.15 / (A/A₀)²

Density
1,200 kg/m³
Velocity
1.59 m/s
ζ
0.15
Kv
4,131 m³/h
ΔP
0.002 bar
Drop fully open
0.002 bar
OKVelocity at most 2 m/s

The loss coefficient ζ of a fully open knife gate is small (typically 0.15), and it rises steeply as the blade covers the bore. The maker's data decides the final size.

2. Thrust and operator

F = q·π·D + 0.5·d² + μ·ΔP·π/4·D² ± W   ·   T = F·lead / (2π·η)

Seat friction
1.88 kN
Packing friction
0.29 kN
Pressure load on the seat
1.88 kN
Blade weight
0.04 kN
Pressure acting on the stem
0.18 kN
Design thrust (with 25 % margin)
5.24 kN
Stem
Ø 24 mm · stroke 220 mm
Stem torque
22 N·m
Rim pull at the handwheel
120 N

Operator

The thrust is small enough for a handwheel: about 28 turns to open or close.

3. Closing time and water hammer

tcrit = 2L / a   ·   ΔP ≈ 2·ρ·L·Δv / t (Michaud)   ·   teff = 0.35 · tstroke

Wave speed
800 m/s
Stroke time
41 s
Effective closing time (35 % of the stroke)
14.4 s
Critical time 2L / a
0.4 s
Pressure surge
0.4 bar
Allowed surge
0.5 bar
Minimum safe stroke time
33 s
OKThe closing time is slow enough.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.