Knife gate valves
A flat blade that slices through thick, dirty flow: the valve for slurry, sewage, pulp and powders.
Step 5 of 6
5Calculations
Three checks make the selection safe: the pressure drop with the blade at its working height, the thrust and the operator it needs, and the closing time that protects the pipe from water hammer.
1. Flow and pressure drop
Kv = 0.04·DN² / √ζ · ΔP = ζ·ρ·v² / 2 · ζ = 0.15 / (A/A₀)²
- Density
- 1,200 kg/m³
- Velocity
- 1.59 m/s
- ζ
- 0.15
- Kv
- 4,131 m³/h
- ΔP
- 0.002 bar
- Drop fully open
- 0.002 bar
The loss coefficient ζ of a fully open knife gate is small (typically 0.15), and it rises steeply as the blade covers the bore. The maker's data decides the final size.
2. Thrust and operator
F = q·π·D + 0.5·d² + μ·ΔP·π/4·D² ± W · T = F·lead / (2π·η)
- Seat friction
- 1.88 kN
- Packing friction
- 0.29 kN
- Pressure load on the seat
- 1.88 kN
- Blade weight
- 0.04 kN
- Pressure acting on the stem
- 0.18 kN
- Design thrust (with 25 % margin)
- 5.24 kN
- Stem
- Ø 24 mm · stroke 220 mm
- Stem torque
- 22 N·m
- Rim pull at the handwheel
- 120 N
Operator
The thrust is small enough for a handwheel: about 28 turns to open or close.
3. Closing time and water hammer
tcrit = 2L / a · ΔP ≈ 2·ρ·L·Δv / t (Michaud) · teff = 0.35 · tstroke
- Wave speed
- 800 m/s
- Stroke time
- 41 s
- Effective closing time (35 % of the stroke)
- 14.4 s
- Critical time 2L / a
- 0.4 s
- Pressure surge
- 0.4 bar
- Allowed surge
- 0.5 bar
- Minimum safe stroke time
- 33 s
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.