Lift check valves
A disc or piston that the flow lifts straight off its seat and gravity or a spring drops back.
Step 5 of 6
5Calculations
Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to lift the disc against its weight and the spring, and the closing surge when the pump stops.
1. Flow and pressure drop
Kv = 0.04·DN² / √ζ · Cv = 1.156·Kv · ΔP = ζ·ρ·v² / 2
- Density
- 1,000 kg/m³
- Velocity
- 2.48 m/s
- ζ
- 6.50
- Kv / Cv
- 157 / 181
- ΔP
- 0.20 bar
- Drop with the disc fully lifted
- 0.20 bar
2. Holding the disc lifted
vmin = 35·√V (ft/s), V = specific volume (ft³/lb)
- Minimum velocity to hold it open
- 2.31 m/s
- Velocity
- 2.48 m/s
- How far the disc is lifted
- 100 %
- Cracking pressure
- 24 mbar
Typical figures. The cracking pressure is set by the weight of the disc and the spring: it is the pressure difference that first lifts the disc. The maker's data decides.
3. Closing surge (slam)
a = (P/ρ)/L ≤ v/0.5 · vrev = a·tclose · ΔP = ρ·c·vimpact
- Wave speed
- 1000 m/s
- How fast the flow slows
- 3.33 m/s²
- Time for the disc to drop back
- 0.06 s
- Reverse velocity as it closes
- 0.20 m/s
- Velocity at impact
- 0.14 m/s
- Closing surge
- 1.4 bar
- Allowed surge
- 2.0 bar
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.