← Non-return valves

Lift check valves

A disc or piston that the flow lifts straight off its seat and gravity or a spring drops back.

Your dutyClean waterDN 10010 bar20 °C70 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to lift the disc against its weight and the spring, and the closing surge when the pump stops.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
2.48 m/s
ζ
6.50
Kv / Cv
157 / 181
ΔP
0.20 bar
Drop with the disc fully lifted
0.20 bar
OKVelocity at most 3 m/s

2. Holding the disc lifted

vmin = 35·√V (ft/s), V = specific volume (ft³/lb)

Minimum velocity to hold it open
2.31 m/s
Velocity
2.48 m/s
How far the disc is lifted
100 %
Cracking pressure
24 mbar
OKThe flow is enough to hold the disc fully lifted.

Typical figures. The cracking pressure is set by the weight of the disc and the spring: it is the pressure difference that first lifts the disc. The maker's data decides.

3. Closing surge (slam)

a = (P/ρ)/L ≤ v/0.5   ·   vrev = a·tclose   ·   ΔP = ρ·c·vimpact

Wave speed
1000 m/s
How fast the flow slows
3.33 m/s²
Time for the disc to drop back
0.06 s
Reverse velocity as it closes
0.20 m/s
Velocity at impact
0.14 m/s
Closing surge
1.4 bar
Allowed surge
2.0 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.