Nozzle check valves
A spring-loaded plug that slides along the pipe and shuts before the flow can turn back.
Nozzle check valves are classified in several ways at once: by the guide, by the strength of the spring, by the body, and by the seat. Each option below has its own 3D cutaway.
11. By guide: single or double
The guide decides how the plug is held straight as it slides. A single guide holds the stem at the rear. A double guide holds the nose too.
Single guide
The stem runs in one bush, in a hub behind the plug.
How it works
The plug is carried on its stem. The stem slides through the rear bush, so the plug moves straight along the pipe.
Strengths
- ✓Simple and cheap.
- ✓Fewer parts in the flow.
- ✓Lowest loss.
Limits
- !The nose is free, so a heavy plug can wobble in turbulent flow.
Where it is used
- •Small and medium valves.
- •Steady, clean flow.
Double guide
A pin at the nose runs in a second hub upstream, as well as the rear stem.
How it works
The plug is held at both ends. The front pin keeps the nose true, so the plug cannot tilt or buzz, even in uneven flow.
Strengths
- ✓Steadier in turbulent flow.
- ✓Less wear on the guides.
- ✓Good for large plugs.
Limits
- !A second hub adds a little loss and cost.
- !More parts to inspect.
Where it is used
- •Large valves.
- •After pumps and bends.
- •Gas and steam.
22. By spring: light, standard or heavy
The spring decides how much flow it takes to hold the plug open, and how hard it is pushed shut. Light springs suit low flows; heavy springs suit fast stops.
Light spring
A weak coil: it opens at a very low flow, but closes a little more slowly.
How it works
The plug lifts at a low pressure, so the valve opens fully at a small flow and the loss is low.
Strengths
- ✓Opens at a very low flow.
- ✓The smallest cracking pressure.
Limits
- !The slowest of the three to close.
- !Less able to follow a fast stop.
Where it is used
- •Low flows.
- •Gravity feed and low-head lines.
Standard spring
The usual coil: a good balance of holding speed and quick closing.
How it works
It holds the plug open at a normal line speed and shuts it fast when the flow stops.
Strengths
- ✓A good balance.
- ✓Suits most pump lines.
Limits
- !A small pressure loss to open.
- !Needs a steady flow.
Where it is used
- •Most pump discharge lines.
Heavy spring
A strong coil: the fastest close and the least slam, but it needs more flow to hold open.
How it works
The strong spring pushes the plug back sooner, so there is almost no reverse flow even on a fast pump trip.
Strengths
- ✓The fastest close.
- ✓The least slam.
Limits
- !Needs a higher flow to hold open.
- !A higher cracking pressure.
Where it is used
- •Long pump lines.
- •Fast pump trips.
33. By body: flanged, wafer or welded
The body decides the length, weight and how the valve is joined to the pipes.
Flanged
A body with its own flange at each end, bolted to the pipe flanges.
How it works
The plug, nozzle and guide sit inside a bulged shell. The shell is bolted between the pipe flanges.
Strengths
- ✓Every size and rating.
- ✓Can be taken out of the line.
- ✓Strong.
Limits
- !Heavier and dearer.
- !More leak points.
Where it is used
- •Process plants.
- •Pump stations and pipelines.
Wafer
A short body clamped between the pipe flanges by long studs.
How it works
The studs run the full length of the body and clamp it between the pipe flanges. It has no flanges of its own.
Strengths
- ✓The shortest and lightest.
- ✓Cheaper than flanged.
Limits
- !A limit on size and pressure.
- !Cannot be removed with one side of the pipe live.
Where it is used
- •Small and medium lines.
- •Low pressure.
Welded
A body with weld ends, joined to the pipe by butt welds.
How it works
The shell is welded straight into the pipe, with no flange joints that could leak.
Strengths
- ✓No flange leak points.
- ✓Strong at high pressure.
- ✓Good for buried lines.
Limits
- !Cannot be unbolted: repair is by cutting.
- !Needs welding and testing on site.
Where it is used
- •High pressure.
- •Buried and hazardous lines.
44. By seat: metal or resilient
The seat is what the plug closes on. It decides the tightness and the temperature the valve can take.
Metal seat
Metal on metal, with a hard-faced band on the plug and nozzle.
How it works
The plug closes on a hard band in the throat of the nozzle. It takes heat and does not wear in clean fluids.
Strengths
- ✓Takes high temperature.
- ✓Very hard-wearing.
- ✓Fire-safe by nature.
Limits
- !Leaks a little.
- !Grit can stop it sealing.
Where it is used
- •Steam and hot oil.
- •High pressure.
Resilient seat
A rubber ring on the plug presses into the nozzle throat.
How it works
The soft ring presses into the metal and fills the tiny gaps, so the valve seals drop-tight.
Strengths
- ✓Drop-tight sealing.
- ✓Seals on a little grit.
Limits
- !Limited in temperature and fluid.
- !The rubber can wear or swell.
Where it is used
- •Water lines.
- •Low-pressure gas.
Metal (13 % chrome or bronze)
A plain metal seat for water, oil and gas. It is hard and cheap and allows a small leak.
Water, oil, gas
Hard-faced metal
A harder alloy overlay for high temperature, steam and abrasive fluids.
Steam, hot oil, wear
EPDM rubber
A rubber ring for hot and cold water and many chemicals. Not for oils.
Water, air, dilute chemicals
NBR (nitrile)
A rubber ring that stands up to oils and fuels. Limited in heat.
Oils, fuels, gas
FKM (fluoroelastomer)
A rubber for hot oils and many chemicals. Dearer than EPDM or NBR.
Hot oils, chemicals
55. Plug and stem materials
The plug, stem and bush are wet by the fluid and rub against each other, so their material matters as much as the body.
Bronze
Good for fresh water and mild service. Not for seawater, strong chemicals or steam.
Fresh water
Stainless steel 304
A general-purpose stainless steel for water, air and many fluids.
Water, air, food
Stainless steel 316
Stainless steel with better resistance to chloride and chemicals.
Seawater, chemicals
Duplex stainless steel
Stronger and more resistant to chloride cracking. For harsh and high-pressure service.
Seawater, sour service
66. Standards
These are the main standards a specification or datasheet refers to.
| Standard | Covers | Typical use |
|---|---|---|
| API 6D / ISO 14313 | Pipeline valves, including axial check valves | Oil, gas and water pipelines |
| API 594 | Check valves: flanged, lug, wafer and butt-welding | Process plants |
| ASME B16.34 | Pressure-temperature ratings of valves | Rating selection |
| API 598 / EN 12266 | Shell and seat tests, and leakage classes | Acceptance testing |
| ASME B16.10 | Face-to-face and end-to-end lengths | Checking the length against the pipe |
Check the current edition and the project specification: they decide which standard applies. Many axial checks are built to the maker's own design to one of these.
77. Why this model and not another?
A nozzle check is the quiet, low-slam choice for clean lines that stop fast, but not for every duty. Here is how to choose.
| If your duty is… | Nozzle | Dual-plate | Swing check | Tilting disc |
|---|---|---|---|---|
| Pump that may stop fast | Best choice | Good: spring-closed | Needs lever and dashpot | Good |
| Gas or steam line | Best choice | Good | Fair | Fair |
| Water or sewage with solids | Poor: jams the guide | Poor: plates jam | Best choice | Poor |
| Compact, light valve in a clean line | Fair: longer body | Best choice | Heavy and long | Heavy |
| Very large pump discharge line | Good | Heavy plates | Heavy and slow | Best choice |
| Vertical line, flow up or down | Good: any position | Good: any position | Only up | Only up |
| Pulsating flow (reciprocating pump) | Fair | Poor | Poor | Poor |
Choose a nozzle check when…
Choose it when
- ✓The pump can trip and a surge would harm the line.
- ✓The fluid is clean.
- ✓You want the lowest slam and a smooth flow.
- ✓The valve will be fitted in any position.
Do not choose it when
- ✗Solids, sewage or slurry.
- ✗A tight space: the body is longer.
- ✗A tight budget for a simple job.
Choose a dual-plate or swing check when…
Choose it when
- ✓Space, weight or cost matter.
- ✓The fluid has some solids (swing check).
- ✓The line is short and the stop is gentle.
Do not choose it when
- ✗Long pump lines that stop fast, with no aid.
- ✗Very low flow.
Choose a tilting disc when…
Choose it when
- ✓The pipe is very large.
- ✓You need a clear bore and low loss.
- ✓The pump can trip and the line is long.
Do not choose it when
- ✗Dirty fluids with solids.
- ✗A small pipe, where a nozzle is lighter.
Common mistakes
- !Using a nozzle check on sewage: rags jam the guide and the stem.
- !Choosing the valve at the pipe size: at low flow the plug does not open fully and flutters on its spring.
- !Fitting it straight after a pump or a bend: the uneven flow makes the plug buzz. Leave a few pipe diameters of straight run.
- !Using a heavy spring on a gentle service: the plug needs more flow than the line can give.
- !Forgetting the pressure drop to open: a heavy spring costs a little head all the time.
💡 Rule of thumb: nozzle check for clean lines that must stop fast without a bang; dual-plate where space matters; swing check where there are solids; tilting disc for very large lines.