Plunger valves
An in-line valve for large pressure drops: the water flows straight through a smooth ring between two bodies, and a hollow plunger uncovers the windows of a control cylinder, so the water is throttled in many fine jets and does not cavitate.
A plunger valve is one design. What you choose is how it is driven, how the body is made and how it seals. The control cylinder is the same part in every valve, with its perforations matched to the duty.
11. The control cylinder: one part, tuned to the duty
Every plunger valve has the same control cylinder: a fixed tube at the outlet with a band of slots or perforations in its wall. It is not a choice of valve type. The maker drills the perforations coarser or finer to suit the duty: the finer they are, the higher the resistance coefficient ξ and the less the water cavitates, but the less water the valve passes. The sizing pages work out the right perforation for you.
What it does
The plunger uncovers the slots one after another as it is drawn back, so the water goes in through many small jets instead of one big one.
The same in every plunger valve
Tuned, not chosen
For a mild drop the slots are large and the valve passes the most water. For a large drop the perforations are finer (ξ up to about 150), which takes the pressure drop in small steps.
Set by the sizing calculation
The trade-off
Finer perforations pass less water, so the valve must be larger for the same flow. If even the finest cannot take the drop, share it between two valves in series.
Check the stroke stays between 10 and 90 %
22. By drive: handwheel or actuator
Both work through the same crank. The drive decides how fast the plunger moves and how it is operated.
Handwheel
A handwheel on the crank shaft, turned by hand.
How it works
A gearbox between the handwheel and the crank multiplies the force. The stroke is slow, which is good for a long pipeline.
Strengths
- ✓Simple and cheap
- ✓A slow stroke limits surge
Limits
- !Slow for large valves
- !Not for remote control
Where it is used
- •Small and medium valves
- •Manual flow adjustment
Actuator
An electric or hydraulic actuator on the crank shaft.
How it works
The actuator turns the crank through a gearbox. A positioner or a controller sets the position from a signal.
Strengths
- ✓Remote or automatic control
- ✓Faster stroke, with limit switches
Limits
- !Dearer
- !A fast stroke can make a surge on a long pipe
Where it is used
- •Large valves
- •Automatic control and buried valves
33. By body: cast or welded
The body holds the pressure and the control cylinder, and decides the size and pressure the valve can take.
Cast
A cast iron or cast steel body.
How it works
The casting is made in one piece with the chamber and outlet. It suits the usual sizes and pressures.
Strengths
- ✓Good for most sizes
- ✓Lower cost in production
Limits
- !Limited at very large sizes and high pressure
Where it is used
- •Water supply
- •Pump stations
Welded
A body welded from steel plate.
How it works
Plates are rolled and welded into a body. It can be made in any size and for high pressure.
Strengths
- ✓Very large sizes
- ✓High pressures
Limits
- !More work to make
- !Welds must be inspected
Where it is used
- •Dams and large transmission lines
- •High-head outlets
44. By seal: metal or rubber
The seal rings on the plunger decide how tightly the valve shuts.
Metal seal
Metal rings or a metal-to-metal fit.
How it works
Metal rings take heat and dirt, but leak a little.
Strengths
- ✓Strong and long-lasting
- ✓Takes heat and dirt
Limits
- !A small leak is normal
Where it is used
- •Hot water
- •Raw water with grit
Rubber seal
Rubber seal rings on the plunger.
How it works
The rubber seal rings press on the control cylinder and seal drop-tight.
Strengths
- ✓Drop-tight
- ✓Seals on a little dirt
Limits
- !Limited by temperature
- !Rubber ages
Where it is used
- •Drinking water
- •Most water supply valves
EPDM
Water, seawater and sewage up to about 120 °C. The usual rubber for water.
Water supply and treatment
NBR (nitrile)
Oil, fuel and air up to about 100 °C.
Fuel and oily water
FKM (fluoroelastomer)
Oil, fuels and many chemicals up to about 200 °C.
Chemical and hot service
Metal on metal
Hot water and where a small leak is accepted.
Hot service
55. Plunger and cylinder materials
The plunger and the control cylinder are in fast water all the time and rub together. They must not corrode, pit or score.
Stainless steel 316
The usual choice for the control cylinder and plunger in water and wastewater. It resists corrosion and wear.
Water supply, treatment, reservoirs
Duplex stainless steel
For seawater and saline water: high strength and resistance to chlorides.
Seawater and brackish water
Hard-faced surfaces
A hard overlay on the plunger, the cylinder edges and the rings where grit or cavitation wears them.
Raw water with sand, severe duty
66. Standards
These are the main standards a specification or datasheet refers to.
| Standard | What it covers | Used for |
|---|---|---|
| EN 1074-1 | Valves for water supply: general requirements | Water supply valves, the main design reference |
| EN 1074-5 | Control valves for water supply | Regulating valves in water supply |
| EN 12266-1 | Testing of valves: pressure and leak tests | Factory tests |
| ISO 5208 | Pressure testing of valves | Factory tests |
| EN 1092-1 / ASME B16.5 | Flanges | End connections |
Check the current edition and the project specification: the standard in the tender decides.
77. Why this valve and not another?
A plunger valve is the right choice for controlling water across a large pressure drop. For a small drop, or where length matters, a simpler valve is better.
| Valve | Large drop | Cavitation | Drive force | Length |
|---|---|---|---|---|
| Plunger valve | Very good | Very good, with fine perforations | Low (balanced) | Long |
| Globe valve | Good | Fair | High | Short |
| Needle valve | Very good | Good | Low | Long, small sizes |
| Ball valve (V-port) | Fair | Fair | Medium | Short |
| Butterfly valve | Poor | Poor | Medium | Very short |
| Diaphragm valve | Fair | Fair | Low | Medium |
| Gate valve | Not for throttling | Poor | High | Medium |
Plunger valve
Choose it when
- ✓A large pressure drop that could cavitate
- ✓Water, with a long, slow stroke accepted
- ✓A small drive force is wanted
Do not choose it when
- ✗A small pressure drop
- ✗Short face-to-face length is needed
- ✗Slurry with solids that clog the windows
Globe valve
Choose it when
- ✓A moderate drop and a short body
- ✓Small to medium sizes
Do not choose it when
- ✗A large drop that would cavitate
Butterfly valve
Choose it when
- ✓A small drop and a large pipe
- ✓A short, light valve
Do not choose it when
- ✗Any large drop: it cavitates
Common mistakes
- !Taking the capacity of the coarsest perforation and then fitting a finer cylinder: it passes much less water.
- !Choosing the perforation by valve size and not by the pressure drop and outlet pressure.
- !Throttling at a small opening, where the valve cavitates more and the control is poor.
- !Closing it too fast on a long pipeline, and making a surge.
- !Using it on water with solids that block the windows.
💡 Rule of thumb: use the coarsest perforation that keeps σ above 1.1 times the limiting index at the working opening, and keep the stroke between 10 and 90 %.