← Non-return valves

Swing check valves

A hinged disc that the flow pushes open, and that swings shut by itself when the flow stops.

Swing check valves are classified in several ways at once: by how the hinge is arranged, by what helps the disc to close, by the body, and by the seat. Each option below has its own 3D cutaway.

11. By hinge: inside or through the body

The hinge pin can stay sealed inside the body, or pass out through it so something outside can act on the disc.

1

Internal hinge

The hinge pin is held inside the body, with plugs in the ends of its holes.

Forward flowDrag to rotate · hover a dot for its name

How it works

The pin and its lugs are cast into the cover pocket and the pin ends are plugged. Nothing passes through the wall.

Strengths

  • ✓No leak path along the pin.
  • ✓Fewer parts and no packing to maintain.
  • ✓Cheaper.

Limits

  • !Nothing outside shows the disc position.
  • !No lever, weight or dashpot can be fitted.

Where it is used

  • •Clean water and general lines.
  • •Small and medium valves.
2

External hinge (through pin)

The hinge pin passes out through the body, through a packed boss.

Forward flowDrag to rotate · hover a dot for its name

How it works

A packing and gland seal the pin where it leaves the body. Outside, an indicator, a lever with a weight, or a lever with a dashpot can be fitted.

Strengths

  • ✓The disc position can be seen from outside.
  • ✓Lets a closing aid be fitted.
  • ✓The disc can be adjusted without opening the cover.

Limits

  • !A packing that can leak.
  • !More parts and more cost.

Where it is used

  • •Pump discharge lines.
  • •Sewage and large water lines.

22. By what helps it close

A plain disc closes by gravity alone. Where the line is long or the pump stops fast, the disc needs help to close in time and gently.

1

No aid (gravity)

The disc closes by its own weight, once the flow has stopped.

Forward flowDrag to rotate · hover a dot for its name

How it works

The disc hangs from the hinge. When the flow slows, gravity pulls it down to the seat.

Strengths

  • ✓Simplest and cheapest.
  • ✓No outside parts.

Limits

  • !Closes late, so the reverse flow can build up.
  • !May slam in long or fast-stopping lines.

Where it is used

  • •Short lines and gentle pump stops.
  • •Gravity drains and low-pressure lines.
2

Outside lever and counterweight

A lever on the hinge pin carries a weight that pulls the disc shut sooner.

Forward flowDrag to rotate · hover a dot for its name

How it works

The weight acts through the lever, so the disc starts to close as the flow slows, before it reverses.

Strengths

  • ✓Closes earlier than a plain disc.
  • ✓Easy to adjust by sliding the weight.
  • ✓Shows the disc position.

Limits

  • !Raises the flow needed to hold the disc open.
  • !Takes more room at the side.

Where it is used

  • •Pump stations.
  • •Water and sewage lines.
3

Lever with oil dashpot

A lever, weight and an oil dashpot that cushions the last part of the swing.

Forward flowDrag to rotate · hover a dot for its name

How it works

The weight starts the closing, and the dashpot slows the disc just before it seats, so it lands softly.

Strengths

  • ✓Cuts the closing surge a lot.
  • ✓Adjustable damping.

Limits

  • !More parts and oil to maintain.
  • !Still needs a fast-closing check on very fast pump trips.

Where it is used

  • •Long pump lines.
  • •Water transmission mains.

33. By body: bolted cover, wafer or pressure seal

The body decides the size, weight and pressure the valve can take, and how it is serviced.

1

Bolted cover (flanged)

A full flanged body with a bolted cover over the disc.

Forward flowDrag to rotate · hover a dot for its name

How it works

The cover lifts off for access, so the disc and seat can be changed with the valve still in the line.

Strengths

  • ✓Serviced in line.
  • ✓Full bore and low loss.
  • ✓Every size and rating.

Limits

  • !Long and heavy.
  • !Needs headroom above for the cover.

Where it is used

  • •Most pump and pipeline duties.
  • •Large sizes.
2

Wafer

A short body between the pipe flanges, held by the flange bolts.

Forward flowDrag to rotate · hover a dot for its name

How it works

The valve has no flanges of its own. A hump on top holds the hinge, and the disc swings into the pipe.

Strengths

  • ✓Light, short and cheap.
  • ✓Fits where space is tight.

Limits

  • !Cannot be serviced in line.
  • !A higher loss and a limit on size and pressure.

Where it is used

  • •Small and medium water lines.
  • •Low pressure.
3

Pressure seal

A forged body with a cover that is sealed by the line pressure itself.

Forward flowDrag to rotate · hover a dot for its name

How it works

A soft ring around the cover is squeezed by the pressure, so the higher the pressure, the tighter the joint. The ends are welded to the pipe.

Strengths

  • ✓For very high pressure and temperature.
  • ✓No flange joint to leak.

Limits

  • !Dear.
  • !Harder to open and service.

Where it is used

  • •Power plants and high-pressure pipelines.
  • •Steam and boiler feed.

44. By seat: metal or resilient

The seat is what the disc closes on. It decides the tightness and the temperature the valve can take.

1

Metal seat

A hard metal disc seats on a hard metal ring.

Forward flowDrag to rotate · hover a dot for its name

How it works

The two faces are machined or hard-faced to match. The seal is metal on metal, so it is strong but not perfectly tight.

Strengths

  • ✓Strong and long-lasting.
  • ✓Takes high temperature and dirty fluids.
  • ✓Little wear.

Limits

  • !A small leak is normal.
  • !Needs a clean, smooth seat.

Where it is used

  • •Steam, oil, gas and hot water.
  • •Dirty fluids.
2

Resilient (rubber-faced) seat

A rubber face on the disc presses into the seat.

Forward flowDrag to rotate · hover a dot for its name

How it works

The rubber is squeezed by the back pressure and fills small scratches, so the valve seals drop-tight.

Strengths

  • ✓Drop-tight shut-off.
  • ✓Quiet closing.
  • ✓Seals past small grit.

Limits

  • !Limited temperature.
  • !The rubber ages and can be cut.

Where it is used

  • •Water and sewage.
  • •Cold, clean liquids.

Metal (13 % chrome or bronze)

Hard and strong. Good for hot water, oil and gas up to about 425 °C. Leaks a little.

Typical use: steam, hot water, oil, general service

Hard-faced metal

A very hard alloy welded on the seat and disc. For high temperature and wear.

Typical use: steam, high temperature, erosive fluids

EPDM rubber

Water, seawater and sewage up to about 120 °C. Not for oil.

Typical use: water supply, sewage

NBR (nitrile)

Oil, fuel and gas up to about 100 °C. Not for sunlight or strong acids.

Typical use: oil, fuel, air and gas lines

FKM (fluoroelastomer)

Oil, fuels and many chemicals up to about 200 °C. Dearer.

Typical use: chemicals, hot oils

55. Disc and pin materials

The disc, arm and hinge pin are wet by the fluid and rub against each other, so their material matters as much as the body.

Bronze

Good for fresh and raw water. Not for seawater with fast flow, strong chemicals or steam.

Typical use: water supply, fire lines

Stainless steel 304

Water, air, oil and mild chemicals.

Typical use: general service

Stainless steel 316

Chemicals, chlorides and hot service.

Typical use: process and hot lines

Duplex stainless steel

Seawater and high chloride fluids. Strong and resistant.

Typical use: seawater, offshore

66. Standards

These are the main standards a specification or datasheet refers to.

StandardCoversTypical use
API 594Check valves: flanged, lug, wafer and butt-weldingProcess plants and pipelines
BS 1868 / API 6DSteel swing check valves, and pipeline check valvesOil, gas and water pipelines
AWWA C508Swing check valves for waterworksWater supply
ASME B16.34Pressure-temperature ratings of valvesRating selection
API 598 / EN 12266Shell and seat tests, and leakage classesAcceptance testing

Check the current edition and the project specification: they decide which standard applies.

77. Why this model and not another?

A swing check is the first choice for many lines, but another check valve is often better. Here is how to choose.

If your duty is…Swing checkDual-plateTilting discNozzle
Water or sewage with solidsBest choicePoor: plates jamFairPoor
Pump line where the pump may stop fastNeeds a lever and dashpotGoodGoodBest choice
Compact, light valve in a small lineWafer type is goodBest choiceHeavyFair
Very large pipelineHeavyHeavyBest choiceGood
Pulsating flow (reciprocating pump)Poor: disc chattersPoorPoorFair
Low flow, below the holding velocityPoor: disc fluttersFairFairGood
Cheapest valve for a simple jobBest choiceGoodDearDear

Choose a swing check when…

Choose it when

  • ✓The fluid is clean water or has solids.
  • ✓The flow is steady and strong enough to hold the disc open.
  • ✓You want low loss and a clear bore.
  • ✓You can service it in line.

Do not choose it when

  • ✗Pulsating flow from a reciprocating pump.
  • ✗A pump that stops fast in a long line, without an aid.
  • ✗Very low flow, where the disc flutters.

Choose a dual-plate when…

Choose it when

  • ✓Space and weight matter.
  • ✓The line is clean.
  • ✓You want fast, spring-closed shut-off.

Do not choose it when

  • ✗Solids or sewage.
  • ✗Dirty fluids that jam the plates.

Choose a tilting disc or nozzle when…

Choose it when

  • ✓The pump can trip and the line is long.
  • ✓You need low slam and a quick close.
  • ✓The pipe is very large.

Do not choose it when

  • ✗A tight budget for a simple job.
  • ✗Dirty fluids with solids.

Common mistakes

  • !Choosing the check valve at the pipe size: at low flow the disc never opens fully and flutters.
  • !Ignoring slam in a long pump line, and fitting a plain disc.
  • !Fitting it upside down, with the hinge below, or in a vertical line with the flow downward.
  • !Using a swing check on a reciprocating pump: the pulses make the disc chatter.
  • !Forgetting that the cover needs headroom above to be lifted.

💡 Rule of thumb: swing check for steady water flow; add a lever and dashpot for long pump lines; change to a nozzle or tilting disc when the stop is fast.