← Learn

Valve actuators

The muscle behind a quarter-turn valve: it turns the stem with air, electricity or oil, on command, and brings the valve home if the power is lost.

Your duty120 N·m6 bar400 V4 sCloseEdit duty

Step 5 of 6

5Calculations

Each result shows its formula and inputs, and a pass or CHECK. The figures are typical, not brand data.

1. Torque

Trequired = Tvalve · SF   ·   T(p) = T(6 bar) · p / 6 · spring end torque ≥ T required

Valve torque
120 N·m
Safety factor
× 1.25
Required torque
150 N·m
Actuator size
150 N·m
Air torque at this supply
195 N·m (1.30 ×)
Spring torque at the end of the stroke
150 N·m (1.00 ×)
OKThe actuator gives the required torque.

Sized on the lowest supply. A spring-return actuator is checked on both the spring and the air.

2. Air use and stroke time

T · (π/2) = p · ΔV · η   ·   Vfree = ΔV · (p + 1.013) / 1.013   ·   t = Vfree / Q

Swept volume per stroke
0.57 L
Free air per stroke
3.9 Nl
Stroke time
0.4 s (wanted 4.0 s)
OKThe actuator is not slower than wanted. If it is much faster, fit a flow control to slow it and avoid a water hammer.

Stroke time uses a solenoid and tubing of about 600 Nl/min. A bigger solenoid makes it faster.

3. Fail-safe action

The springs close the valve when the air is lost.

OKThis type can give the action wanted.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.