Valve actuators
The muscle behind a quarter-turn valve: it turns the stem with air, electricity or oil, on command, and brings the valve home if the power is lost.
Step 4 of 6
4Site & supply
Check the actuator against the site: the temperature, the area and the supply.
Site and supply
Spring-return pneumatic (-40 to 80 °C)
- Site temperature
- -5 … 45 °C
- Supply
- 6 bar g
- Mounting
- ISO 5211 flange, a size for about 150 N·m
- Design standard
- ISO 5211, part-turn actuator attachment
OKThe site temperature is inside the range of this type.OKThe area is not hazardous.
What the supply must be
Clean, dry instrument air at a stable pressure. The spring end torque, not the air, sets the safe action.
Before ordering, confirm: the lowest air pressure, the supply voltage, the cable entries, the enclosure rating, the paint and the mounting position.
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.