← Non-return valves

Ball check valves

A ball that the flow pushes off its seat, and that rolls or is pushed back to stop the reverse flow.

Your dutyClean waterDN 10010 bar20 °C70 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to push the ball clear against its weight and the spring, and the closing surge when the pump stops.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
2.48 m/s
ζ
2.00
Kv / Cv
283 / 327
ΔP
0.061 bar
Drop with the ball fully clear
0.061 bar
OKVelocity at most 3 m/s

2. Holding the ball clear

vmin = 35·√V (ft/s), V = specific volume (ft³/lb)

Minimum velocity to hold it open
1.93 m/s
Velocity
2.48 m/s
How far the ball is pushed clear
100 %
Cracking pressure
24 mbar
OKThe flow is enough to hold the ball fully clear of the seat.

Typical figures. The cracking pressure is set by the weight of the ball and the spring: it is the pressure difference that first moves the ball. The maker's data decides.

3. Closing surge (slam)

a = (P/ρ)/L ≤ v/0.5   ·   vrev = a·tclose   ·   ΔP = ρ·c·vimpact

Wave speed
1000 m/s
How fast the flow slows
3.33 m/s²
Time for the ball to come back
0.08 s
Reverse velocity as it closes
0.27 m/s
Velocity at impact
0.16 m/s
Closing surge
1.6 bar
Allowed surge
2.0 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.