Ball check valves
A ball that the flow pushes off its seat, and that rolls or is pushed back to stop the reverse flow.
Step 5 of 6
5Calculations
Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to push the ball clear against its weight and the spring, and the closing surge when the pump stops.
1. Flow and pressure drop
Kv = 0.04·DN² / √ζ · Cv = 1.156·Kv · ΔP = ζ·ρ·v² / 2
- Density
- 1,000 kg/m³
- Velocity
- 2.48 m/s
- ζ
- 2.00
- Kv / Cv
- 283 / 327
- ΔP
- 0.061 bar
- Drop with the ball fully clear
- 0.061 bar
2. Holding the ball clear
vmin = 35·√V (ft/s), V = specific volume (ft³/lb)
- Minimum velocity to hold it open
- 1.93 m/s
- Velocity
- 2.48 m/s
- How far the ball is pushed clear
- 100 %
- Cracking pressure
- 24 mbar
Typical figures. The cracking pressure is set by the weight of the ball and the spring: it is the pressure difference that first moves the ball. The maker's data decides.
3. Closing surge (slam)
a = (P/ρ)/L ≤ v/0.5 · vrev = a·tclose · ΔP = ρ·c·vimpact
- Wave speed
- 1000 m/s
- How fast the flow slows
- 3.33 m/s²
- Time for the ball to come back
- 0.08 s
- Reverse velocity as it closes
- 0.27 m/s
- Velocity at impact
- 0.16 m/s
- Closing surge
- 1.6 bar
- Allowed surge
- 2.0 bar
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.