Ball check valves
A ball that the flow pushes off its seat, and that rolls or is pushed back to stop the reverse flow.
Step 2 of 6
2Type
First decide whether a ball check is the right check valve, then choose the ball movement, the spring and the body. The rules below are typical practice; you can override them.
Suitability of a dual-plate check valve
Good fitA ball check is a good choice for this duty.
Why
- →A ball check has a moderate pressure loss, because the ball stays in the stream. Check the drop in the last step.
- →In small sizes a ball check is compact, simple and cheap.
- →Clean liquid is no problem: use a cage type with a light spring if you want a quick close.
- →In a pump line it stops the flow running back when the pump stops. Check the closing surge in the last step.
Your valve
Recommended values are filled in. Change any of them and the later steps follow.
- Ball movement
- A side chamber: the ball rolls out of the way, for sewage, slurry and rags.
- Spring
- No spring: the ball closes by weight and rolling, so fit it vertically or on a slope.
- Body
- Its own flanges: every size and rating, and easy to remove.
What to ask for in the specification
These follow from the duty. Put them on the datasheet.
- ✓Spring setting. Set the spring against the closing surge, and check that your normal flow still pushes the ball fully clear.
- ✓Ball material. The ball must be round, smooth and light enough to lift on your flow. Ask for a rubber-covered ball for sewage and water, and a metal ball for hot or oily fluids.
- ✓Orientation. Fit a spring-less ball check in a vertical line with the flow upward, or on a slope. With a spring it can go in any position. Keep the arrow on the body pointing with the flow.
- ✓Clean-out cover. Ask for a clean-out cover so the valve can be opened and cleared if rags jam the ball, without taking it out of the line.
- ✓Drain connection. A drain plug lets the body be emptied before it is taken out.
- ✓Pressure test. Every valve should be shell-tested and seat-tested to API 598 or EN 12266, with a certificate.
See all types with 3D models →
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.