← Isolation valves

Diaphragm valves

A valve that closes by pressing a flexible diaphragm onto a weir or a flat seat: the fluid touches only the body and the diaphragm, so the stem never leaks and the valve suits slurries, chemicals and clean duties.

Your dutyCorrosive chemicalDN 806 → 5 bar20 °C60 m³/hEdit duty

Step 5 of 6

5Calculations

These are the checks on the chosen valve. Each shows its formula, the numbers, and OK or CHECK.

1. Flow and stroke

Kv = Q·√(SG / ΔP)   ·  Kvs = 0.04·DN² / √ζ   ·   Kv/Kvs = 1 − (1 − x)n

Pressure drop ΔP
1.00 bar
Kv required
62.9
ζ
4.5
Kvs / Cvs
121 / 140
Kv required as a fraction of Kvs
52 %
Stroke needed
34 %
Stroke of the diaphragm centre
30 mm
Velocity in the pipe
3.32 m/s
OKThe stroke is within the usual range.CHECKThe usual limit for this fluid is 2 m/s.

The characteristic is typical of the design: quick opening, so most of the flow comes in the first half of the stroke. Replace it with the manufacturer's curve for the real valve.

  • !The velocity is above the usual limit for this service.

2. Cavitation and choked flow

σ = (P2 + Patm − Pv) / ΔP   ·   OK when σ ≥ 1.1 · σL

σ
5.99
Limiting index σL
2.49
Margin (σ ÷ 1.1σL)
2.19
Choked-flow drop
3.4 bar
OKThe index is above the limit: no cavitation expected.OKThe drop is below the choked-flow limit.

The limiting indices are typical values for the design, not brand data. Replace them with the manufacturer's curves for the real valve.

3. Closing thrust and the operator

F = (0.1·P1 + q) · A · 1.2   ·   T = F·L / (2π·η)

Effective area of the diaphragm
41 cm²
Closing thrust
5.86 kN
Lead of the spindle thread
6 mm
Handwheel torque
18.7 Nm
Handwheel diameter
240 mm
Rim force
156 N
Stroke time
10 s
OKThe rim force is within 250 N that a person can pull.

The thrust is the line pressure over the diaphragm plus the load that seals it, with a 20 % margin. Replace it with the manufacturer's thrust table for the real valve.

4. Closing surge

tcrit = 2L / a   ·   ΔP = ρ·a·v · min(1, tcrit / tclose)

Wave speed
1100 m/s
Critical time 2L/a
0.2 s
Stroke time
10 s
Surge
0.72 bar
Allowed rise
1.2 bar
OKThe surge is within the allowed rise.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.