1. Flow and stroke
Kv = Q·√(SG / ΔP) · Kvs = 0.04·DN² / √ζ · Kv/Kvs = 1 − (1 − x)n
- Pressure drop ΔP
- 1.00 bar
- Kv required
- 62.9
- ζ
- 4.5
- Kvs / Cvs
- 121 / 140
- Kv required as a fraction of Kvs
- 52 %
- Stroke needed
- 34 %
- Stroke of the diaphragm centre
- 30 mm
- Velocity in the pipe
- 3.32 m/s
The characteristic is typical of the design: quick opening, so most of the flow comes in the first half of the stroke. Replace it with the manufacturer's curve for the real valve.
- !The velocity is above the usual limit for this service.
2. Cavitation and choked flow
σ = (P2 + Patm − Pv) / ΔP · OK when σ ≥ 1.1 · σL
- σ
- 5.99
- Limiting index σL
- 2.49
- Margin (σ ÷ 1.1σL)
- 2.19
- Choked-flow drop
- 3.4 bar
The limiting indices are typical values for the design, not brand data. Replace them with the manufacturer's curves for the real valve.
3. Closing thrust and the operator
F = (0.1·P1 + q) · A · 1.2 · T = F·L / (2π·η)
- Effective area of the diaphragm
- 41 cm²
- Closing thrust
- 5.86 kN
- Lead of the spindle thread
- 6 mm
- Handwheel torque
- 18.7 Nm
- Handwheel diameter
- 240 mm
- Rim force
- 156 N
- Stroke time
- 10 s
The thrust is the line pressure over the diaphragm plus the load that seals it, with a 20 % margin. Replace it with the manufacturer's thrust table for the real valve.
4. Closing surge
tcrit = 2L / a · ΔP = ρ·a·v · min(1, tcrit / tclose)
- Wave speed
- 1100 m/s
- Critical time 2L/a
- 0.2 s
- Stroke time
- 10 s
- Surge
- 0.72 bar
- Allowed rise
- 1.2 bar
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.