Diaphragm valves
A valve that closes by pressing a flexible diaphragm onto a weir or a flat seat: the fluid touches only the body and the diaphragm, so the stem never leaks and the valve suits slurries, chemicals and clean duties.
Step 2 of 6
2Type
First decide whether a diaphragm valve is the right valve, then choose its design, its operator and its body.
Is it the right valve?
Good fitA diaphragm valve is a good choice for this duty.
Why
- →The spindle, bonnet and actuator never touch the fluid, so nothing can leak out along the spindle and the fluid cannot corrode them.
- →Chemicals are what the valve is made for: a PTFE-faced diaphragm and a lined or plastic body give the fluid only resistant materials to meet.
- →The weir design closes tightly with a short stroke, can throttle in a limited way and suits clean liquids and chemicals.
Build the valve
The recommended choices are set. Change any of them.
- Design
- The weir design: the most common, with a short stroke and tight shut-off, for clean liquids and chemicals.
- Operator
- A handwheel: simple and cheap, for hand operation and small or low-pressure valves.
- Body
- Plastic: resists many chemicals at low pressure and temperature; the rating falls fast as it gets hot.
What the valve needs
These follow from the duty and the choices. Put them on the datasheet.
- ✓Sealed spindle. The spindle and bonnet are isolated from the fluid by the diaphragm, so there is no stem packing to leak. Check the bonnet has a tell-tale hole so a failed diaphragm shows.
- ✓Spare diaphragms. The diaphragm is a wear part: keep spares, and change it on a schedule, not only when it leaks.
- ✓Handwheel. A handwheel with a rising spindle shows the position. Check the rim force is within what a person can pull.
- ✓Slow closing. On a long pipe a fast closure makes a surge. Slow the stroke, with a handwheel or a speed control on the actuator.
- ✓Installation position. Fit the valve with the weir at an angle (about 45 °) or the straight-through valve drain-down, so the body empties.
- ✓Hydrostatic test. Test the body and the seat to EN 12266-1 and note the test pressure on the datasheet.
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.