← Regulating valves

Globe valves

A valve that throttles by moving a plug straight onto a seat: the fluid rises through the seat and leaves high on the other side, and the plug's shape sets how the flow changes with the lift.

Your dutyClean waterDN 8010 → 8 bar20 °C40 m³/hEdit duty

Step 5 of 6

5Calculations

These are the checks on the chosen valve. Each shows its formula, the numbers, and OK or CHECK.

1. Flow and stroke

Kv = Q·√(SG / ΔP)   ·   Kvs = 0.04·DN² / √ζ   ·   Kv/Kvs = R^(x − 1), R = 50

Pressure drop ΔP
2.00 bar
Kv required
28.3
ζ
6.0
Kvs / Cvs
105 / 121
Kv required as a fraction of Kvs
27 %
Stroke needed
67 %
Stroke of the plug
25 mm
Velocity in the pipe
2.21 m/s
OKThe stroke is within the usual range.OKThe usual limit for this fluid is 3 m/s.

The characteristic is the standard curve for the plug. Replace it with the manufacturer's curve for the real valve.

2. Cavitation and choked flow

σ = (P2 + Patm − Pv) / ΔP   ·   OK when σ ≥ 1.1 · σL   ·   ΔPchoked = FL²·(P1 − FF·Pv)

σ
4.49
Limiting index σL
1.75
Margin (σ ÷ 1.1σL)
2.33
Choked-flow drop
8.9 bar
OKThe index is above the limit: no cavitation expected.OKThe drop is below the choked-flow limit.

The limiting indices are typical values for the trim, not brand data. Replace them with the manufacturer's curves for the real valve.

3. Thrust and the operator

F = (0.1·P1·A·u + q·π·d·n + Fpack) · 1.2   ·   d = √(4·1.25·F / (π·k·0.1·p_air))

Seat diameter
72 mm
Stem thrust to shut
6.65 kN
Air supply pressure
6 bar g
Actuator diameter needed
188 mm
Standard actuator
200 mm
Stroke time
1 s
OKA standard actuator gives the thrust.

The thrust is the pressure force on the plug, plus the load that seals the seat and the friction of the packing, with a 20 % margin. A balanced trim cuts the first part. Replace it with the manufacturer's thrust table for the real valve.

4. Seat leakage

Leakage class
VI
Allowed leakage at this drop
0.80 ml/min

Class VI: a soft seat is bubble-tight, with only a few drops a minute allowed.

5. Closing surge

tcrit = 2L / a   ·   ΔP = ρ·a·v · min(1, tcrit / tclose)

Wave speed
1000 m/s
Critical time 2L/a
0.2 s
Stroke time
1 s
Surge
4.42 bar
Allowed rise
2.0 bar
CHECKThe surge is above the allowed rise: close more slowly.
  • !The closing surge is above the allowed rise. Close more slowly, or add a speed control.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.