Globe valves
A valve that throttles by moving a plug straight onto a seat: the fluid rises through the seat and leaves high on the other side, and the plug's shape sets how the flow changes with the lift.
Step 2 of 6
2Type
First decide whether a globe valve is the right valve, then choose its trim, plug, seat, service trim and operator.
Is it the right valve?
Good fitA globe valve is a good choice for this duty.
Why
- →Throttling is what the globe valve is made for: the gap between plug and seat can be set to any size, and the plug's shape sets the characteristic.
- →The plug seats on a round seat ring, so the valve shuts off well: class IV with a metal seat and class VI with a soft seat.
- →Clean water is easy for this valve.
Build the valve
The recommended choices are set. Change any of them.
- Trim
- One plug on one seat: the tightest shut-off, but the thrust is the highest.
- Characteristic
- Equal percentage: for a valve that takes a small or changing share of the drop, as in a pumped system.
- Seat
- A soft insert: bubble-tight, class VI, but not above about 200 °C and not for cavitation or grit.
- Service trim
- A plain plug and seat for modest pressure drops.
- Operator
- Spring return: the spring moves the valve to its safe position when the air is lost.
What the valve needs
These follow from the duty and the choices. Put them on the datasheet.
- ✓Flow direction. Fit the valve with the flow under the plug, as the arrow on the body shows. Fitted the wrong way round it throttles badly and the packing carries the full pressure when shut.
- ✓Stem packing. Choose the packing for the fluid and the temperature: PTFE for most liquids, graphite for steam and heat. Check it is tight after the first heating.
- ✓Air supply. The actuator needs clean, dry instrument air at the pressure used in the sizing, with a filter regulator.
- ✓Limit switches. Fit open and closed limit switches or a position feedback unit so the control system knows where the valve is.
- ✓Positioner. Throttling needs a positioner: it sets the stroke from the control signal and overcomes the friction of the packing.
- ✓Slow closing. On a long pipe a fast closure makes a surge. Slow the stroke, with a handwheel or a speed control on the actuator.
- ✓Seat leakage test. State the leakage class on the datasheet, and test to it: class IV for a metal seat and class VI for a soft seat.
- ✓Spares. Keep a set of packing, gaskets and a spare plug and seat, which are the parts that wear.
- ✓Hydrostatic test. Test the body and the seat to EN 12266-1 and note the test pressure on the datasheet.
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.