← Isolation valves

Plug valves

A quarter-turn valve: a plug with a port turns in the body, and the port lines up with the pipe or turns its back on it. Four designs seal it in four ways: grease, a PTFE sleeve, a swing-out plug, or a plug that lifts first.

Your dutyGasDN 10030 → 29 bar20 °C200 m³/hEdit duty

Step 5 of 6

5Calculations

These are the checks on the chosen valve. Each shows its formula, the numbers, and OK or CHECK.

1. Flow and turn

Kv = Q·√(SG / ΔP)   ·   Kvs = 0.04·DN² / √ζ   ·   Kv/Kvs = sin(α)n

Pressure drop ΔP
1.00 bar
Kv required
200.0
ζ
0.80
Kvs / Cvs
447 / 517
Kv required as a fraction of Kvs
45 %
Turn needed from shut
37°
Velocity in the pipe
7.07 m/s
OKThe turn is within the usual range.OKThe usual limit for this fluid is 20 m/s.

The flow curve is a typical one for the design: a rectangular port passes most of the flow in the first half of the turn. Replace it with the manufacturer's curve for the real valve.

2. Cavitation and choked flow

The liquid checks do not apply to gas or steam. A large drop gives high noise and choked flow: ask the manufacturer for the capacity and the noise level.

3. Torque and the operator

T = 1.25 · T0 · (DN/100)2.6 · (1 + P1/Pref)   ·   F = T / L

Torque to turn
124 N·m
Lever length
750 mm
Pull at the lever or handwheel
165 N
Time for the quarter turn
4 s
OKThe pull is within 250 N that a person can give.

The torque is typical for the design and rises with the size and the pressure: a lift plug needs the least at pressure and a sleeved plug the most. It includes a 25 % margin. Replace it with the manufacturer's torque table for the real valve.

4. Closing surge

There is no water hammer in a gas or steam line, so no surge check is needed.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.