Plug valves
A quarter-turn valve: a plug with a port turns in the body, and the port lines up with the pipe or turns its back on it. Four designs seal it in four ways: grease, a PTFE sleeve, a swing-out plug, or a plug that lifts first.
Step 5 of 6
5Calculations
These are the checks on the chosen valve. Each shows its formula, the numbers, and OK or CHECK.
1. Flow and turn
Kv = Q·√(SG / ΔP) · Kvs = 0.04·DN² / √ζ · Kv/Kvs = sin(α)n
- Pressure drop ΔP
- 1.00 bar
- Kv required
- 200.0
- ζ
- 0.80
- Kvs / Cvs
- 447 / 517
- Kv required as a fraction of Kvs
- 45 %
- Turn needed from shut
- 37°
- Velocity in the pipe
- 7.07 m/s
The flow curve is a typical one for the design: a rectangular port passes most of the flow in the first half of the turn. Replace it with the manufacturer's curve for the real valve.
2. Cavitation and choked flow
The liquid checks do not apply to gas or steam. A large drop gives high noise and choked flow: ask the manufacturer for the capacity and the noise level.
3. Torque and the operator
T = 1.25 · T0 · (DN/100)2.6 · (1 + P1/Pref) · F = T / L
- Torque to turn
- 124 N·m
- Lever length
- 750 mm
- Pull at the lever or handwheel
- 165 N
- Time for the quarter turn
- 4 s
The torque is typical for the design and rises with the size and the pressure: a lift plug needs the least at pressure and a sleeved plug the most. It includes a 25 % margin. Replace it with the manufacturer's torque table for the real valve.
4. Closing surge
There is no water hammer in a gas or steam line, so no surge check is needed.
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.