← Isolation valves

Plug valves

A quarter-turn valve: a plug with a port turns in the body, and the port lines up with the pipe or turns its back on it. Four designs seal it in four ways: grease, a PTFE sleeve, a swing-out plug, or a plug that lifts first.

Your dutyGasDN 10030 → 29 bar20 °C200 m³/hEdit duty

Step 2 of 6

2Type

First decide whether a plug valve is the right valve, then choose its design, port and operator.

Is it the right valve?

Good fit

A plug valve is a good choice for this duty.

Why

  • →A quarter turn opens or closes it, so it is fast, and the lever shows the position.
  • →The plug seals against the body or a sleeve or a seat all round, so the shut-off is tight.
  • →Oil and gas are what the lubricated and lift plug valves are made for: a steel body, a tight seal, and a design that is fire-safe.

Build the valve

The recommended choices are set. Change any of them.

Design
Grease seals a tapered plug: tight, for oil, gas and steam, up to high pressure. It needs grease, so it is not for clean water.
Port
A rectangular port about two thirds of the pipe: a smaller plug and a lower torque.
Operator
A lever: simple and cheap, for small and medium valves.
  • !The sizing method is for liquids. For gas or steam, check the capacity with the manufacturer.

What the valve needs

These follow from the duty and the choices. Put them on the datasheet.

  • ✓Travel stops. Fit stops that limit the turn to exactly 90 degrees, so the port lines up with the pipe and the plug seats.
  • ✓Lubricant. Choose a sealant for the fluid and the temperature, and grease the valve on a schedule through the lubricator screw. Without grease it sticks and leaks.
  • ✓Lever or handwheel. A lever or handwheel shows the position. Check the pull is within what a person can give.
  • ✓Fire-safe design. For oil, gas and hazardous fluids ask for a fire-safe design tested to API 607 or ISO 10497, with an anti-static device and a blow-out-proof stem.
  • ✓Leakage test. State the leakage rate on the datasheet and test to it. Plug valves are usually tested for no visible leakage.
  • ✓Spares. Keep a set of packing and gaskets, and for a sleeved valve a spare sleeve, which are the parts that wear.
  • ✓Hydrostatic test. Test the body and the seat to API 598 or EN 12266-1 and note the test pressure on the datasheet.

Read about the types →

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.