Air valves

Valves at the high points of a water pipe that let air out and in: small automatic air release valves, large air and vacuum valves, and double- and triple-function valves that do both.

Your dutyClean waterDN 10010 bar20 °C70 m³/hEdit duty

Step 5 of 6

5Calculations

Four checks make the selection safe: the air to let out, the orifice, the float, and the number of valves.

1. Air to let out

Qair = 0.02 · Q   (free air, at atmospheric pressure)

Flow
70 m³/h
Velocity in the main
2.48 m/s
Air to let out (free air)
1.40 m³/h

Typical rule: about 2 % of the water flow by volume comes out of the water as air at atmospheric pressure (AWWA M51). It is less in hot water and more in cold, turbulent or pumped water.

2. Orifice

ṁ = Cd·A·P1·√(γ/RT)·(2/(γ+1))(γ+1)/2(γ−1)   (P1 / Patm ≥ 1.89, choked)

Air the orifice can pass
9.38 m³/h
Air to let out (free air)
1.40 m³/h
Valves needed at one high point
1
OKThe orifice passes at least the air that must be let out.

3. Float and lever

Pmax = λ · Ffloat / Aorifice   ·   Ffloat = (ρ·V − m)·g

Float diameter
70 mm
Lever ratio
8 : 1
Force of the float (net buoyancy)
1.2 N
Force of the pressure on the orifice
2.0 N
Highest pressure the float can hold
49.1 bar
Working pressure
10.0 bar
OKThe float can hold the orifice shut at this pressure.

5. How many and where

Valves at each high point
1
Typical spacing on a long level run
600 m
Valves along the line (minimum)
1

Count the real high points from the profile of the pipe: this number only shows how many a long level run needs. Fit the valve with an isolating valve.

  • !An air release valve does not let air in. Where the pipe can drain, add an air and vacuum valve or use a combination valve.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.