Air valves
Valves at the high points of a water pipe that let air out and in: small automatic air release valves, large air and vacuum valves, and double- and triple-function valves that do both.
Step 6 of 6
6Summary
Everything you chose, in one place. Copy it into a datasheet or print it.
Duty
- Fluid
- Clean water
- Main pipe size
- DN 100
- Pressure
- 10 bar g
- Temperature
- 20 °C
- Flow
- 70 m³/h
Valve
- Valve
- Air release valve
- Function
- Air release
- Mechanism
- Lever
- Orifice
- 1.6 mm
- Body
- Plastic
Materials
- Body material
- Cast iron
- Seat
- EPDM rubber
Body and rating
- Pressure class
- Class 150 (19.6 bar)
- Connection size
- DN 25
- Overall height
- 230 mm
Checks
- Air to let out
- 1.40 m³/h
- Orifice capacity
- 9.38 m³/h
- Highest pressure held
- 49.1 bar
- Valves per point / along line
- 1 / 1
Standards and requirements
- Design standard
- EN 1074-4
- Tests
- EN 12266; API 598
- Also ask for
- Position; Isolating valve; Vacuum protection; Drain and chamber
- !An air release valve does not let air in. Where the pipe can drain, add an air and vacuum valve or use a combination valve.
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.