← Non-return valves

Foot valves

A check valve with a strainer on the end of a pump's suction pipe: it keeps the rubbish out and the pipe full.

Your dutyClean waterDN 10010 bar20 °C70 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the flow, the pressure drop and the suction limit, whether the flow lifts the disc, and the closing surge when the pump stops.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
2.48 m/s
ζ
3.77
Kv / Cv
206 / 238
ΔP
0.12 bar
Drop with the disc fully lifted
0.12 bar
Strainer open area, and hole size
4 × pipe area · 3 mm
Drop with the strainer half blocked
0.13 bar
OKVelocity at most 3 m/s
CHECKThe suction velocity should stay below 1.5 m/sOKWith the strainer half blocked the drop should stay below 0.3 bar
  • !The velocity is above 1.5 m/s, which is too fast for a suction pipe. The pump has no pressure to spare, and it will cavitate. Use a larger foot valve and suction pipe.

2. Holding the disc lifted

vmin = 35·√V (ft/s), V = specific volume (ft³/lb)

Minimum velocity to hold it open
2.12 m/s
Velocity
2.48 m/s
How far the disc is lifted
100 %
Cracking pressure
24 mbar
OKThe flow is enough to hold the disc fully lifted.

Typical figures. The cracking pressure is set by the weight of the disc and the spring: it is the suction that first lifts the disc. The maker's data decides.

3. Closing surge (slam)

a = (P/ρ)/L ≤ v/0.5   ·   vrev = a·tclose   ·   ΔP = ρ·c·vimpact

Wave speed
1000 m/s
How fast the flow slows
3.33 m/s²
Time for the disc to drop back
0.09 s
Reverse velocity as it closes
0.30 m/s
Velocity at impact
0.18 m/s
Closing surge
1.8 bar
Allowed surge
2.0 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.