← Non-return valves

Foot valves

A check valve with a strainer on the end of a pump's suction pipe: it keeps the rubbish out and the pipe full.

Your dutyClean waterDN 10010 bar20 °C70 m³/hEdit duty

Step 2 of 6

2Type

First decide whether a foot valve is the right valve, then choose the disc, the spring, the strainer and the body. The rules below are typical practice; you can override them.

Suitability of a dual-plate check valve

Good fit

A foot valve is a good choice for this duty.

Why

  • →A foot valve holds the water in the suction pipe when the pump stops, so the pump stays primed and starts at once.
  • →It is the last part on the suction side, so its loss must be small: the pump pulls the water in and has little pressure to spare. Check the suction velocity and the drop with a half-blocked strainer in the calc step.
  • →Its strainer keeps stones, leaves and fish out of the pump and off the seat. The strainer's open area must be several times the pipe's.
  • →In clean water a fine slot screen is a good choice to keep sand out of the pump.
  • →It suits a pump above the water, such as a well pump or a transfer pump, that is not self-priming.
  • →Because the pump pulls the water in, every bit of loss in the valve and strainer reduces the pressure left at the pump inlet.
  • →In small sizes the foot valve is cheap and compact, and a plastic body may do.

Your valve

Recommended values are filled in. Change any of them and the later steps follow.

Disc
A poppet on a stem: seals well, for small and medium sizes.
Spring
No spring: the weight of the disc and the water closes it, for tall pipes.
Strainer
A slot screen: keeps out fine sand, for clean water.
Body
Its own flange: every size and rating, and easy to take apart.

What to ask for in the specification

These follow from the duty. Put them on the datasheet.

  • ✓Submergence. Keep the valve well under the water, with enough water above the strainer that no whirlpool forms and no air is drawn in. Check the lowest water level in the dry season.
  • ✓Strainer area. The open area of the strainer must be at least four to six times the pipe's. A smaller one clogs quickly and the pump starves.
  • ✓Orientation. Fit the foot valve upright with the strainer at the bottom and the pipe going up, and keep the strainer off the floor so the water can enter all round it.
  • ✓Test. The valve is tested for shell strength and seat leakage before it leaves the factory. Ask for the test certificate.

See all types with 3D models →

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.