← Non-return valves

Foot valves

A check valve with a strainer on the end of a pump's suction pipe: it keeps the rubbish out and the pipe full.

Your dutyClean waterDN 10010 bar20 °C70 m³/hEdit duty

Step 4 of 6

4Body and rating

Read off the pressure class and the length of the valve. Soft seats limit the pressure and temperature below what the body alone could take.

Pressure class needed

Class 150 (19.6 bar @ 20 °C)

The smallest class that covers the pressure is chosen. Tap another one to override.

Face-to-face length
300 mm
Design standard
BS 1868 (steel check valves)

Check: the flange standard of the pipe matches the valve, the face-to-face length fits, the valve stands upright under the lowest water level, and the strainer stands off the floor.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.