← Regulating valves

Plunger valves

An in-line valve for large pressure drops: the water flows straight through a smooth ring between two bodies, and a hollow plunger uncovers the windows of a control cylinder, so the water is throttled in many fine jets and does not cavitate.

Your dutyClean waterDN 30011 → 8 bar20 °C700 m³/hEdit duty

Step 5 of 6

5Calculations

Four checks make the selection safe: the capacity and stroke, the cavitation, the drive, and the closing surge.

1. Capacity and stroke

Kv = Q·√(SG / ΔP)   ·  Kvs = 0.04·DN² / √ξ   ·   stroke = Kv / Kvs

Pressure drop
3.00 bar
Kv needed
404
ξ
5.3
Kvs / Cvs
1,564 / 1,808
Stroke needed
26 %
Velocity in the pipe
2.75 m/s
OKThe stroke is between 10 and 90 %: a good working range.OKVelocity at most 3 m/s

2. Cavitation

σ = Pout / (ΔP + v²/2g)   (m water)   ·   OK when σ ≥ 1.1 · σL

σ
2.97
Limiting index σL at this stroke
2.02
Margin σ / (1.1·σL)
1.34
Choked pressure drop
8.7 bar
OKThe index is above the limit with the safety factor: no cavitation.OKThe drop is below the choked drop.

The limiting indices are typical values for each perforation, not brand data. Replace them with the manufacturer's curves for the real valve. The outlet pressure is taken as absolute, in metres of water.

3. Drive: the slider-crank

s = r(1 − cosθ) + l − √(l² − r²sin²θ)   ·   stroke = 2r

Stroke of the plunger
75 mm
Crank radius
38 mm
Connecting rod length
131 mm
Crank angle for the stroke needed
55°
Time for the full stroke
50 s

The stroke is a quarter of the bore and equals twice the crank radius. The motion is not in exact proportion to the angle: near the ends of the turn the plunger moves more slowly.

4. Closing surge

tcrit = 2L / a   ·   ΔP = ρ·a·v · min(1, tcrit / tclose)

Wave speed
1000 m/s
Critical time 2L/a
1.0 s
Time for the full stroke
50 s
Closing surge
0.55 bar
Allowed surge
2.2 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.