Plunger valves
An in-line valve for large pressure drops: the water flows straight through a smooth ring between two bodies, and a hollow plunger uncovers the windows of a control cylinder, so the water is throttled in many fine jets and does not cavitate.
Step 5 of 6
5Calculations
Four checks make the selection safe: the capacity and stroke, the cavitation, the drive, and the closing surge.
1. Capacity and stroke
Kv = Q·√(SG / ΔP) · Kvs = 0.04·DN² / √ξ · stroke = Kv / Kvs
- Pressure drop
- 3.00 bar
- Kv needed
- 404
- ξ
- 5.3
- Kvs / Cvs
- 1,564 / 1,808
- Stroke needed
- 26 %
- Velocity in the pipe
- 2.75 m/s
2. Cavitation
σ = Pout / (ΔP + v²/2g) (m water) · OK when σ ≥ 1.1 · σL
- σ
- 2.97
- Limiting index σL at this stroke
- 2.02
- Margin σ / (1.1·σL)
- 1.34
- Choked pressure drop
- 8.7 bar
The limiting indices are typical values for each perforation, not brand data. Replace them with the manufacturer's curves for the real valve. The outlet pressure is taken as absolute, in metres of water.
3. Drive: the slider-crank
s = r(1 − cosθ) + l − √(l² − r²sin²θ) · stroke = 2r
- Stroke of the plunger
- 75 mm
- Crank radius
- 38 mm
- Connecting rod length
- 131 mm
- Crank angle for the stroke needed
- 55°
- Time for the full stroke
- 50 s
The stroke is a quarter of the bore and equals twice the crank radius. The motion is not in exact proportion to the angle: near the ends of the turn the plunger moves more slowly.
4. Closing surge
tcrit = 2L / a · ΔP = ρ·a·v · min(1, tcrit / tclose)
- Wave speed
- 1000 m/s
- Critical time 2L/a
- 1.0 s
- Time for the full stroke
- 50 s
- Closing surge
- 0.55 bar
- Allowed surge
- 2.2 bar
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.