← Regulating valves

Plunger valves

An in-line valve for large pressure drops: the water flows straight through a smooth ring between two bodies, and a hollow plunger uncovers the windows of a control cylinder, so the water is throttled in many fine jets and does not cavitate.

Your dutyClean waterDN 30011 → 8 bar20 °C700 m³/hEdit duty

Step 2 of 6

2Type

First decide whether a plunger valve is the right valve, then choose the perforation of its control cylinder, the drive and the body.

Suitability of a plunger valve

Good fit

A plunger valve is a good choice for this duty.

Why

  • →The water goes straight through, in line with the pipe and along a smooth ring, so the loss is low when it is open.
  • →The plunger is pressure-balanced, so a small drive can move it.
  • →It is made for a large pressure drop: the drop is taken in many small steps in the control cylinder.
  • →The perforation of the control cylinder sets the resistance, and the right one keeps the valve out of cavitation.
  • →The characteristic is close to linear: the flow is in proportion to the stroke, which makes control easy.
  • →In clean water a stainless control cylinder with a rubber seal is a good choice.
  • →The stroke is slow, which is good for a long pipeline because it makes little surge.
  • →The body is long, because the plunger and control cylinder sit inside it. Allow for the length.

Your valve

Recommended values are filled in. Change any of them and the checks update.

Cylinder
Coarse slots: the highest capacity, for a mild pressure drop.
Drive
A handwheel through the crank: simple, with a slow stroke. For small and medium valves.
Body
A cast body: for the usual sizes and pressures.

What to ask for in the specification

These follow from the duty. Put them on the datasheet.

  • ✓Balanced plunger. The plunger is open at the back so the pressure acts on both faces. Ask for the drive force at the highest pressure.
  • ✓Control cylinder perforation and capacity curve. Ask for the Kvs with the chosen perforation and the limiting cavitation index σL against stroke, from the manufacturer.
  • ✓Position transmitter. A position signal from the crank or the rod, so the stroke can be read and controlled.
  • ✓Handwheel and indicator. A handwheel with a position indicator and a number of turns for the full stroke.
  • ✓Surge check. Check the closing surge for the stroke time and the length of the pipeline.
  • ✓Test. The valve is tested for shell strength and seal leakage before it is shipped.

See all types with 3D models →

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.