← Protection valves

Pressure reducing valves

A self-acting valve that cuts a high supply pressure to a lower, steady one, whatever the supply or the demand does.

Your dutySteamDN 507 → 4 bar170 °C600 kg/hEdit duty

Step 6 of 6

6Summary

The duty, the choices and the checks together. Copy it, print it, or start again.

Duty

Fluid
Steam
Size
DN 50
Pressure
7 → 4 bar g
Temperature
170 °C
Flow
600 kg/h

Valve

Type
Pressure reducing valve
Design
Direct-acting
Seat
Metal seat
Sensing
External sensing
Body
Bronze
Spring range
2 – 6 bar g

Body and rating

Rating
11.2 bar
Face to face
230 mm

Checks

Kvs
30 (Cv 35)
Opening needed
27 %
Droop
0.20 bar
Lock-up
4.40 bar g
Outlet velocity
32.2 m/s
Failure flow
2,200 kg/h

Standards and needs

Design standard
EN 1349
Tests
EN 12266-1; IEC 60534; ISO 4126-1
Also needed
Strainer; Isolation valves; Bypass; Gauges; Straight pipe; Sensing; Spring range; Steam trap; Drain; Slow warm-up; Dry steam

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.