Swing check valves
A hinged disc that the flow pushes open, and that swings shut by itself when the flow stops.
Step 5 of 6
5Calculations
Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to hold the disc open, and the closing surge when the pump stops.
1. Flow and pressure drop
Kv = 0.04·DN² / √ζ · Cv = 1.156·Kv · ΔP = ζ·ρ·v² / 2
- Density
- 1,000 kg/m³
- Velocity
- 1.89 m/s
- ζ
- 2.40
- Kv / Cv
- 581 / 672
- ΔP
- 0.043 bar
- Drop with the disc fully open
- 0.043 bar
OKVelocity at most 3 m/s
2. Holding the disc open
vmin = 35·√V (ft/s), V = specific volume (ft³/lb)
- Minimum velocity to hold it open
- 1.49 m/s
- Velocity
- 1.89 m/s
- How far the disc is held open
- 100 %
- Cracking pressure
- 28 mbar
OKThe flow is enough to hold the disc fully open.
Typical figures. The cracking pressure is the small pressure difference that first lifts the disc; a soft seat and a counterweight make it a little higher. The maker's data decides.
3. Closing surge (slam)
a = (P/ρ)/L ≤ v/0.5 · vrev = a·tclose · ΔP = ρ·c·vimpact
- Wave speed
- 1000 m/s
- How fast the flow slows
- 1.20 m/s²
- Time for the disc to swing shut
- 0.17 s
- Reverse velocity as it closes
- 0.21 m/s
- Velocity at impact (after cushioning)
- 0.07 m/s
- Closing surge
- 0.7 bar
- Allowed surge
- 1.2 bar
OKThe closing surge is within the allowed value.
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.