← Non-return valves

Swing check valves

A hinged disc that the flow pushes open, and that swings shut by itself when the flow stops.

Your dutyClean waterDN 1506 bar20 °C120 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to hold the disc open, and the closing surge when the pump stops.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
1.89 m/s
ζ
2.40
Kv / Cv
581 / 672
ΔP
0.043 bar
Drop with the disc fully open
0.043 bar
OKVelocity at most 3 m/s

2. Holding the disc open

vmin = 35·√V (ft/s), V = specific volume (ft³/lb)

Minimum velocity to hold it open
1.49 m/s
Velocity
1.89 m/s
How far the disc is held open
100 %
Cracking pressure
28 mbar
OKThe flow is enough to hold the disc fully open.

Typical figures. The cracking pressure is the small pressure difference that first lifts the disc; a soft seat and a counterweight make it a little higher. The maker's data decides.

3. Closing surge (slam)

a = (P/ρ)/L ≤ v/0.5   ·   vrev = a·tclose   ·   ΔP = ρ·c·vimpact

Wave speed
1000 m/s
How fast the flow slows
1.20 m/s²
Time for the disc to swing shut
0.17 s
Reverse velocity as it closes
0.21 m/s
Velocity at impact (after cushioning)
0.07 m/s
Closing surge
0.7 bar
Allowed surge
1.2 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.