← Non-return valves

Swing check valves

A hinged disc that the flow pushes open, and that swings shut by itself when the flow stops.

Your dutyClean waterDN 1506 bar20 °C120 m³/hEdit duty

Step 4 of 6

4Body and rating

Read off the pressure class and the length of the valve. Soft seats limit the pressure and temperature below what the body alone could take.

Pressure class needed

Class 150 (19.6 bar @ 20 °C)

The smallest class that covers the pressure is chosen. Tap another one to override.

Face-to-face length
76 mm
Design standard
API 594 (check valves)

Check: the flange standard of the pipe matches the valve, there is room above for the cover, and the valve is fitted the right way up.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.