Your dutyClean waterDN 20010 bar20 °C300 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to hold the plates open against the spring, and the closing surge when the pump stops.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
2.65 m/s
ζ
2.04
Kv / Cv
1,120 / 1,295
ΔP
0.072 bar
Drop with the disc fully open
0.072 bar
OKVelocity at most 3 m/s

2. Holding the plates open

vmin = 35·√V (ft/s), V = specific volume (ft³/lb)

Minimum velocity to hold it open
1.54 m/s
Velocity
2.65 m/s
How far the plates are held open
100 %
Cracking pressure
48 mbar
OKThe flow is enough to hold the plates fully open.

Typical figures. The cracking pressure is set by the spring: it is the pressure difference that first opens the plates. The maker's data decides.

3. Closing surge (slam)

a = (P/ρ)/L ≤ v/0.5   ·   vrev = a·tclose   ·   ΔP = ρ·c·vimpact

Wave speed
1000 m/s
How fast the flow slows
3.33 m/s²
Time for the plates to snap shut
0.06 s
Reverse velocity as it closes
0.19 m/s
Velocity at impact
0.19 m/s
Closing surge
1.9 bar
Allowed surge
2.0 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.