← Non-return valves

Dual-plate check valves

Two spring-loaded plates that fold open with the flow and snap shut the moment it slows.

Your dutyClean waterDN 20010 bar20 °C300 m³/hEdit duty

Step 4 of 6

4Body and rating

Read off the pressure class and the length of the valve. Soft seats limit the pressure and temperature below what the body alone could take.

Pressure class needed

Class 150 (19.6 bar @ 20 °C)

The smallest class that covers the pressure is chosen. Tap another one to override.

Face-to-face length
89 mm
Design standard
API 594 (check valves)

Check: the flange standard of the pipe matches the valve, the plates clear the bore of the pipe, and the valve is fitted with the hinge pin vertical.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.