← Non-return valves

Dual-plate check valves

Two spring-loaded plates that fold open with the flow and snap shut the moment it slows.

Your dutyClean waterDN 20010 bar20 °C300 m³/hEdit duty

Step 6 of 6

6Summary

Everything you chose, in one place. Copy it into a datasheet or print it.

Duty

Fluid
Clean water
Flow
Steady flow (centrifugal pump)
Size
DN 200
Pressure
10 bar g
Temperature
20 °C
Flow rate
300 m³/h

Valve

Valve
Dual-plate check valve
Plates
Contoured plates
Spring
Standard spring
Body
Wafer

Materials

Body material
Cast iron
Plates and pin
Bronze
Seat
Metal (13 % chrome or bronze)

Body and rating

Rating
Class 150 (19.6 bar)
Face to face
89 mm

Checks

Pressure drop
0.072 bar
Cv
1,295
Velocity
2.65 m/s
Minimum velocity
1.54 m/s
Cracking pressure
48 mbar
Closing surge
1.9 bar

Standards and requirements

Design standard
API 594
Test standard
API 598; EN 12266
Also specify
Spring chosen for the duty; Stop pin; Full-bore body; Fit it the right way; Centring on the bolts; Drain connection

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.