Dual-plate check valves
Two spring-loaded plates that fold open with the flow and snap shut the moment it slows.
Step 2 of 6
2Type
First decide whether a dual-plate is the right check valve, then choose the plates, the spring and the body. The rules below are typical practice; you can override them.
Suitability of a dual-plate check valve
Good fitA dual-plate check is a good choice for this duty.
Why
- →A dual-plate check is short, light and cheap, and the spring closes it quickly.
- →Clean liquid at a steady flow is its best duty: the plates and pin stay clean.
- →In a pump line it stops the flow running back when the pump stops. Check the closing surge in the last step.
Your valve
Recommended values are filled in. Change any of them and the later steps follow.
- Plates
- Streamlined plates: they lose about 15 % less and open at a lower flow.
- Spring
- The usual spring: a good balance of holding speed and quick closing.
- Body
- A slim ring between the flanges: the lightest and cheapest, for small and medium lines.
What to ask for in the specification
These follow from the duty. Put them on the datasheet.
- ✓Spring chosen for the duty. The spring decides the cracking pressure, the holding flow and the closing speed. Ask the maker to confirm the spring against your minimum and maximum flow and the surge.
- ✓Stop pin. A stop pin across the body catches the open plates, so they cannot flutter against the pipe wall. Ask for it to be retained so it cannot work loose.
- ✓Full-bore body. A full-bore body keeps the loss low. Specify the seat bore and the plate travel.
- ✓Fit it the right way. Fit it with the hinge pin vertical in a horizontal line, or in any position in a vertical line. Keep a straight length of pipe before it so the flow is steady.
- ✓Centring on the bolts. A wafer body is centred on the pipe bolts. Fit the bolts first, and check the plates clear the pipe bore.
- ✓Drain connection. A drain plug lets the body be emptied before it is taken out.
- ✓Pressure test. Every valve should be shell-tested and seat-tested to API 598 or EN 12266, with a certificate.
See all types with 3D models →
Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.