← Non-return valves

Nozzle check valves

A spring-loaded plug that slides along the pipe and shuts before the flow can turn back.

Your dutyClean waterDN 20010 bar20 °C300 m³/hEdit duty

Step 5 of 6

5Calculations

Three checks make the selection safe: the flow and pressure drop, whether the flow is enough to hold the plug open against the spring, and the closing surge when the pump stops.

1. Flow and pressure drop

Kv = 0.04·DN² / √ζ   ·   Cv = 1.156·Kv   ·   ΔP = ζ·ρ·v² / 2

Density
1,000 kg/m³
Velocity
2.65 m/s
ζ
2.30
Kv / Cv
1,055 / 1,220
ΔP
0.081 bar
Drop with the plug fully open
0.081 bar
OKVelocity at most 3 m/s

2. Holding the plug open

vmin = 35·√V (ft/s), V = specific volume (ft³/lb)

Minimum velocity to hold it open
1.11 m/s
Velocity
2.65 m/s
How far the plug is held open
100 %
Cracking pressure
28 mbar
OKThe flow is enough to hold the plug fully open.

Typical figures. The cracking pressure is set by the spring: it is the pressure difference that first lifts the plug. The maker's data decides.

3. Closing surge (slam)

a = (P/ρ)/L ≤ v/0.5   ·   vrev = a·tclose   ·   ΔP = ρ·c·vimpact

Wave speed
1000 m/s
How fast the flow slows
3.33 m/s²
Time for the plug to shut
0.05 s
Reverse velocity as it closes
0.16 m/s
Velocity at impact
0.10 m/s
Closing surge
1.0 bar
Allowed surge
2.0 bar
OKThe closing surge is within the allowed value.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.