← Non-return valves

Nozzle check valves

A spring-loaded plug that slides along the pipe and shuts before the flow can turn back.

Your dutyClean waterDN 20010 bar20 °C300 m³/hEdit duty

Step 4 of 6

4Body and rating

Read off the pressure class and the length of the valve. Soft seats limit the pressure and temperature below what the body alone could take.

Pressure class needed

Class 150 (19.6 bar @ 20 °C)

The smallest class that covers the pressure is chosen. Tap another one to override.

Face-to-face length
210 mm
Design standard
API 594 (check valves)

Check: the flange standard of the pipe matches the valve, the body length fits the pipe, and the arrow on the body points with the flow.

Typical – not brand data. This is a pre-selection. Confirm the final choice with the manufacturer and the project specification.